Middle Atlantic NEXSYS Series - UPS Backup Power with RackLink - 2000VA

2U Rack/Tower - AVR - 8 Hour Recharge - 3 Minute Stand-by - 120 V AC Input - 110 V AC, 120 V AC, 127 V AC Output - Pure Sine Wave - Serial Port - USB - LCD Display - 8 x NEMA 5-20R

Updating...
Checking stock...
available (as of - Refresh Inventory )

FREE SHIPPING ?

Close x
Stock Notification

Notify me when this item comes back in stock

Please note that popular items often become available in small quantities and can sell out again quickly.

Middle Atlantic NEXSYS

Middle Atlantic NEXSYS Line-interactive UPS UPX-RLNK-2000R-2

About the Middle Atlantic NEXSYS

NEXSYS is built on a promise that we've kept for over two decades - more than half the life of the company - that our power products are designed, engineered, and built for AV. It's one thing to say it, it's another thing to prove it. And our NEXSYS Line Interactive UPS backups prove it, we promise. They are built with premium components to keep your AV systems running as smoothly as you'd expect. 2000VA and 20 amp. 8 Outlet UPS with Bank Control, (2) outlet banks with 4 outlets each. An Out-of-Box(y) Experience. Everything is assembled and connected right from the factory saving you time during your installations. Rack ears are pre-installed with the "4-Post" mounting brackets ready to be rack mounted even if you have a 3rd pair of rack rails. The battery is already connected so just plug it in. Customization is a Breeze. The NEXSYS Power Management Software on your PC allows you to customize and configure various settings and notifications if you don't like our default settings - we won't be offended. Set reminders or notifications for things like battery replacement, etc. via email or on the UPS. The IEC Input allows for better cable management of the power cord if shorter or longer cords are required. All UPSs include a 6' (1.8m) IEC power core. Easily locate the IP, MAC address, and device name via the front LCD screen. You can even see the battery installation date. Pure Power. All NEXSYS UPSs have a Pure Sine Wave output and AVR (automatic voltage regulation) providing the cleanest power to your connected equipment, especially the most sensitive equipment. Keep your power squeaky clean. Easily set specific thresholds to switch the unit to battery if the power quality isn't up to your standards. Swap it like it's hot. Hot-swappable battery from the front access panel for easy service without disrupting the system. RackLink Remote Management Built-In. The NEXSYS UPS is RackLink enabled out of the box and discoverable on the RackLink Discovery Tool on PC, Apple, or Android devices. Included RS232 port for control, (2) dry contact ports for alerts, 1 contact is defined to alert users of a battery switchover when the UPS loses utility power or hits a set threshold, 1 contact is defined to alert users when the battery level is low based on usage with customizable thresholds. Energy Star Certified.
Technical Specifications of the Middle Atlantic NEXSYS

General Information

Manufacturer Legrand Group
Manufacturer Part Number UPXRLNK2000R2
Manufacturer Website Address http://www.legrand.us
Brand Name Middle Atlantic
Product Line NEXSYS
Product Name NEXSYS Series 2RU 20 Amp UPS Backup Power System with NEXSYS - 2000VA
Product Type Line-interactive UPS

Technical Information

AVR Yes
Plug/Connector Type NEMA 5-20P
Receptacle Type NEMA 5-20R
Receptacle Detail 8 x NEMA 5-20R
Dataline Protection RJ-45
Cord Length 5.91 ft
Transfer Time 10 ms

Power Description

Load Capacity (VA) 2000 VA
Load Capacity (Watt) 1800 W
Input Voltage 120 V AC
Input Voltage Range 80 V AC - 145 V AC
Output Voltage
  • 110 V AC
  • 120 V AC
  • 127 V AC
Input Current 20 A
Input Frequency 60 Hz
Waveform Type Pure Sine Wave
Surge Energy Rating 1000 J

Display & Graphics

Display LCD

Management

Network Management
  • DB-9 RS-232
  • SmartSlot
  • Network Card
  • Dry Contact

Interfaces/Ports

Serial Port Yes
Network (RJ-45) Yes
USB Yes
EPO Port Yes

Battery Information

DC System Voltage 48 V DC
Battery Chemistry Lead Acid
Backup/Run Time (Full Load) 3 Minute
Backup/Run Time (Half Load) 10 Minute
Typical Battery Recharge Time 8 Hour
Hot Swappable Yes
Replaceable Battery Yes

Environmental Conditions

Minimum Operating Temperature 32°F (0°C)
Maximum Operating Temperature 104°F (40°C)
Storage Temperature 5°F (-15°C) - 113°F (45°C)
Maximum Operating Elevation 9842.52 ft
Operating Humidity 95%
Sound Emission (A-Weighted) 50 dB(A)

Physical Characteristics

Color Family Black
Product Color Black
Height 3.5"
Width 19"
Depth 22"
Rack Height 2U
Form Factor Rack/Tower
Weight (Approximate) 63.05 lb

Miscellaneous

Package Contents
  • NEXSYS 2000VA Rack/tower UPS
  • 6' (1.8m) IEC Power Cord
  • Network Card
Energy Star Yes
Green Compliant Yes
Country of Origin China
Environmental Compliance
  • Restriction of Hazardous Substances (RoHS)
  • Registration, Evaluation, Authorization and Restriction of Chemicals (REACH)

Warranty

Limited Warranty 3 Year
Additional Warranty Information 2 Years Battery
Ratings and Reviews for the Middle Atlantic NEXSYS
Do you own this product? Write a Review
          ( reviews)
% of reviewers would recommend this product to a friend ( out of )
Be the first to write a review
Displaying - of reviews
 | 
x
Write a Review for this product
This question will be posted on a public forum. Do not include HTML, references to other retailers, pricing, personal information, or any profane, inflammatory, or copyrighted comments
Questions about the Middle Atlantic NEXSYS
Do you have questions about this product? Ask Your Question
Be the first to ask a question
Questions | Answers
Displaying - of questions
 | 
Posted on
A:

Answered by: on

out of found this answer helpful

Was this answer helpful? Yes | No

Displaying - of questions
 | 
x
Ask a question about this product

Middle Atlantic NEXSYS Series - UPS Backup Power with RackLink - 2000VA - 2U Rack/Tower - AVR - 8 Hour Recharge - 3 Minute Stand-by - 120 V AC Input - 110 V AC, 120 V AC, 127 V AC Output - Pure Sine Wave - Serial Port - USB - LCD Display - 8 x NEMA 5-20R

This question will be posted on a public forum. Do not include HTML, references to other retailers, pricing, personal information, or any profane, inflammatory, or copyrighted comments
Close x
Answer a question about this product

Middle Atlantic NEXSYS Series - UPS Backup Power with RackLink - 2000VA - 2U Rack/Tower - AVR - 8 Hour Recharge - 3 Minute Stand-by - 120 V AC Input - 110 V AC, 120 V AC, 127 V AC Output - Pure Sine Wave - Serial Port - USB - LCD Display - 8 x NEMA 5-20R

This question will be posted on a public forum. Do not include HTML, references to other retailers, pricing, personal information, or any profane, inflammatory, or copyrighted comments